Feature - Remarks - Tested by
Fire performance The fire performance of MKT VM-ME MPA Technical University of exposed to fire acc. to DIN 4102-9 Braunschweig, Germany
Seismic loads Test of MKT VM-ME under seismic loading IWB University of Stuttgart, Germany
Bond strength Bond resistance of MKT VM-ME Technical University of Kaiserslautern, Germany
Tension Bevaviour in non-cracked and cracked Technical University of concrete, in low and high strength concrete Kaiserslautern, Germany
Wet hole Installation safety tests in wet concrete Technical University of acc. to ETAG 001 TR023 Kaiserslautern, Germany
Under water Installation safety tests in flooded concrete MKT research laboratory, Germany acc. to ETAG 001 part 5
Cyclic loads MKT VM-ME for predominantly cyclic loading University of Dortmund, Germany
Chemical resistance Checking durability of MKT VM-ME Technical University of acc. to ETAG 001 part 5 Kaiserslautern, Germany
Tension in high temperature Tests at high temperature Technical University of Kaiserslautern, Germany
Freeze/thaw Functioning of MKT VM-ME under Technical University of freeze/thaw conditions Kaiserslautern, Germany
Creep Creep test at 50°C, acc. to ETAG 001 TR023 Technical University of Kaiserslautern, Germany
Long term behavior Long term behaviour of MKT VM-ME Technical University of Kaiserslautern, Germany
Corrosion resistance Corrosion resistance of rebar with MKT MPA University of Stuttgart, VM-ME, tests acc. to ETAG 001 TR 023 Germany
Overhead installation Tests for overhead application Technical University of Kaiserslautern, Germany |